Multistandard protection

A comprehensive range to protect against electrical threats, including short circuits, overloads, and earth leakages.

Multi 9
  • Features

    This is a CSA C22.2 No. 5/UL 489 version of the popular Schneider Electric Multi 9™ C60 family of DIN mountable circuit protection devices. (CSA C22.2 No. 5/UL 489 devices provide branch circuit protection, while CSA C22.2 No. 235/UL 1077 supplementary protectors do not.) Designed to meet global applications and code requirements, the CSA/UL Listed Multi 9 breakers are the first product to carry CSA C22.2 No. 5 UL 489, IEC 947-2 as well as the CE mark. The Multi 9 breaker family features an extensive array of accessories.

    Features

    • 1-2-3 pole configurations
    • Seventeen CSA C22.2 No. 5/UL 489 ratings from 0.5A to 35A
    • Two trip curves available: C curve ( 7 to 10 times handle rating); D curve (10 to 14 times handle rating)
    • Small size: less than 19.05 mm (3 /4") wide per pole
    • Interrupting ratings 10K AIR standard
    • System voltages include 120/240Vac and 240Vac; also DC ratings of 60 Vdc (1P) and 125 Vdc (2P)
    • Ring terminals available (with finger-safe option)
    • Padlock attachments for locking in the "OFF" position only
    • Common tripping of all poles
    • Variety of accessories including shunt trip, auxiliary switch, and under-voltage release. Same accessories can be used on both CSA C22.2 No. 235/UL 1077 and CSA C22.2 No. 5/UL 489 devices
    • Mounting base from 12 to 60 poles

    Multi 9 Miniature Supplementary Protectors
    Provide overcurrent protection in applications where branch circuit protection is either already provided or is not required.

    The Multi 9™ supplementary protector line from Schneider Electric is a modular system of supplementary protectors, accessories and installation equipment that makes up the most complete product offering in its class. These CSA C22.2 No. 235 / UL1077 Recognized supplementary protectors provide overcurrent protection in applications where branch circuit protection is either already provided or is not required.

    Features

    • 0.5 to 63 Amps at 480Y/277 VAC
    • Up to 10k AIR
    • 1-, 2-, 3- and 4-pole versions
    • Common tripping of all poles
    • B-curve (between 76.2 and 127 mm (3 & 5 In)), C-curve (between 177.8 and 254 mm (7 & 10 In)), (D-curve between 254 and 355.6 mm (10 & 14 In))
    • Current limiting capability is standard
    • Full line of accessories
    • Only 18 mm width per pole (approximately 3/4 inch)
    • Flush, surface, or DIN rail mountable
    • CSA C22.2 No. 5, UL1077, IEC 60947-2, and CE Marked