distributed analog input Modicon Momentum - 4 Input

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Modicon Momentum automation platform
    product or component type
    Analogue input base
    analogue input number
    4
    analogue input type
    Differential
    analogue input range
    +/- 100 mV 15 bits + sign > 10000 kOhm
    +/- 25 mV 15 bits + sign > 10000 kOhm
    thermocouple type
    Thermocouple B
    Thermocouple K
    Thermocouple T
    Thermocouple J
    Thermocouple E
    Thermocouple S
    Thermocouple R
    Thermocouple N
    Complementary
    data format
    Full 16 bits signed
    absolute accuracy error
    +/- 21 µV 77 °F (25 °C) +/- 25 mV
    +/- 27 µV 77 °F (25 °C) +/- 100 mV
    +/- 46 µV 140 °F (60 °C) +/- 25 mV
    +/- 94 µV 140 °F (60 °C) +/- 100 mV
    temperature probe type
    Ni 100 0.125 mA +/- 25 mV
    Ni 1000 0.125 mA +/- 100 mV
    Pt 100 0.125 mA +/- 25 mV
    Pt 1000 0.125 mA +/- 100 mV
    update time
    500 ms
    isolation between channels
    400 V DC
    isolation between channels and ground
    500 V AC for 1 minute
    isolation between supply and ground
    500 V for 1 minute
    permissible common mode voltage
    100 V DC between channels to ground
    115 V AC single or three phases between channels
    200 V DC between channels
    250 V AC between channels to ground
    250 V AC single phase between channels
    common mode rejection
    120 dB DC between channels
    130 dB 50 Hz AC between channels
    135 dB DC between channels to ground
    140 dB 60 Hz AC between channels
    145 dB 50 Hz AC between channels to ground
    155 dB 60 Hz AC between channels to ground
    serial mode rejection
    35 dB 50 Hz AC
    45 dB 60 Hz AC
    external power requirement
    +/- 30 V DC
    power dissipation in W
    <= 5.5 W
    reverse polarity protection
    Internal
    protection type
    Internal 2 A slow-blow
    associated fuse rating
    500 mA fast blow
    marking
    CE
    local signalling
    4 LEDs channel status
    electrical connection
    2 connectors for removable terminal blocks
    current consumption
    305 mA 24 V DC
    depth
    1.87 in (47.5 mm)
    height
    4.92 in (125 mm)
    width
    5.57 in (141.5 mm)
    product weight
    0.47 lb(US) (0.215 kg)
    Environment
    product certifications
    CSA
    FM Class 1 Division 2
    UL
    protective treatment
    TC
    resistance to electrostatic discharge
    4 kV contact IEC 801-2
    8 kV on air IEC 801-2
    resistance to electromagnetic fields
    9.14 V/yd (10 V/m) 80...1000 MHz IEC 801-3
    ambient air temperature for operation
    32...140 °F (0...60 °C)
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    relative humidity
    95 % without condensation
    operating altitude
    <= 16404.2 ft (5000 m)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • Italian
    • German
    User guide
    Date
    Size
    Add to My Documents
    Embase d'E/S Modicon Momentum, Guide de l'utilisateur (Version 38)
    Modicon Momentum I/O Base, User Guide (Version 21)
    Certificate
    Date
    Size
    Add to My Documents
    EAC_RUCFRME83B00168_MOMENTUM_DEC2014 (Version 1.0)
    Hazloc_cCSAus_225844_70159012_Momentum_feb2018 (Version 1.0)
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Date 11/02/19
    Size 395.6 KB
    CSA_225844_2591646_MOMENTUM_AUG2017 (Version 1.0)
    Instruction Sheet
    Date
    Size
    Add to My Documents
    170AAI52040 4 analog inputs module (Version 03)
    Catalog Pages
    Date
    Size
    Add to My Documents
    Momentum, entrées-sorties analogiques (Version 7.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    ACMA_RCM_MOMENTUM_AUG2013 (Version 1.0)
    Date 19/06/18
    Size 87.5 KB
    DCC_MOMENTUM_JUL2016 (Version 1.0)
    Date 06/08/18
    Size 469.1 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    Modicon Momentum I/O base, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 14/05/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Modicon Momentum I/O base, Product Environmental Profile (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 14/05/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Standard Adapter on a Typical Base
    Dimensions



  • Mounting and Clearance

    Mounting on a Wall



  • Connections and Schema

    External Wiring Diagram



    Internal Pin Connections