Canada

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

Schneider Eletric

View all Modicon Momentum

Modicon Momentum - 170AEC92000

Standard

Schneider Eletric
View all Modicon Momentum
Modicon Momentum - 170AEC92000
Standard

Modicon Momentum - high speed counter module base - 6 I / 4 O

Show more characteristics >
Buy online
No online offers found
Add to My Products Add to My Products

  • Main
    range of product
    Modicon Momentum automation platform
    product or component type
    High speed counter module base
    group of channels
    2 groups of 2 discrete outputs
    2 groups of 3 discrete inputs
    number of counter
    2
    discrete input number
    6
    discrete output number
    4
    Complementary
    discrete input logic
    Positive
    discrete input voltage
    - 3...30 V DC
    24 V DC
    input overvoltage protection
    45 V 10 s
    voltage state 1 guaranteed
    >= 11 V
    voltage state 0 guaranteed
    <= 5 V
    current state 1 guaranteed
    >= 2.5 mA
    current state 0 guaranteed
    <= 1.2 mA
    discrete output logic
    Positive
    discrete output voltage
    24 V
    discrete output current
    1 A per counter
    2 A per module
    0.5 A per point
    voltage drop
    < 0.5 V 0.5 A at state on
    leakage current
    < 1 mA DC 24 V
    surge current
    5 A 1 ms
    response time
    < 0.1 ms from state 0 to state 1 output circuit
    < 0.1 ms from state 1 to state 0 output circuit
    3 ms from state 0 to state 1 input circuit
    3 ms from state 1 to state 0 input circuit
    counting input type
    Absolute SSI up, down with 4 sub-modes
    Incremental up, down, quadrature
    counting input voltage
    24 V single ended
    5 V differential
    counting frequency
    <= 10 kHz single ended
    <= 200 kHz differential
    counter inputs resolution
    24 bits + sign
    counter configuration
    Via comm adapter
    marking
    CE
    electrical connection
    2 connectors for removable terminal blocks
    current consumption
    280 mA 24 V DC
    product weight
    0.46 lb(US) (0.21 kg)
    Environment
    product certifications
    UL
    CSA
    protective treatment
    TC
    resistance to electrostatic discharge
    4 kV contact IEC 801-2
    8 kV on air IEC 801-2
    resistance to electromagnetic fields
    9.14 V/yd (10 V/m) 80...1000 MHz IEC 801-3
    ambient air temperature for operation
    32...140 °F (0...60 °C)
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    relative humidity
    95 % without condensation
    operating altitude
    <= 16404.2 ft (5000 m)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • German
    User guide
    Date
    Size
    Add to My Documents
    170AEC92000 I/O Base with 2 High-Speed Counters, User Manual (Version 08)
    170AEC92000 Embase avec deux compteurs rapides, Manuel utilisateur (Version 08)
    Certificate
    Date
    Size
    Add to My Documents
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Date 29/01/19
    Size 395.6 KB
    EAC_RUCFRME83B00168_MOMENTUM_DEC2014 (Version 1.0)
    Hazloc_cCSAus_225844_70159012_Momentum_feb2018 (Version 1.0)
    CSA_225844_2591646_MOMENTUM_AUG2017 (Version 1.0)
    Instruction Sheet
    Date
    Size
    Add to My Documents
    Momentum Communication Adapter Ground Screw Installation (Version 08)
    Catalog Pages
    Date
    Size
    Add to My Documents
    Momentum, entrées-sorties métiers (Version 5.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    ACMA_RCM_MOMENTUM_AUG2013 (Version 1.0)
    Date 19/06/18
    Size 87.5 KB
    DCC_MOMENTUM_JUL2016 (Version 1.0)
    Date 06/08/18
    Size 469.1 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    Modicon Momentum I/O base, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Modicon Momentum I/O base, Product Environmental Profile (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Standard Adapter on a Typical Base
    Dimensions



  • Mounting and Clearance

    Mounting on a Wall



  • Connections and Schema

    Internal Pin Connections



    External Wiring Diagrams
    Example for Pulse Encoder (5 V)


    Example for Pulse Encoder (24 V)


    Example for Incremental Encoders (RS 422)


    Example for 24 V Pulse Encoder on A, B, and R Lines


    Example for Absolute Encoders with Actuators