Characteristics
Main range of product Modicon Momentum automation platformproduct or component type Discrete relay I/O base ACgroup of channels 2 groups of 4 outputs1 group of 10 inputsdiscrete input number 10 IEC 1131-2 Type 1discrete input logic Positivediscrete input voltage 24...230 V ACdiscrete output number 8discrete output type Relay normally opendiscrete output voltage 24...230 V ACprotective treatment TCComplementary [Us] rated supply voltage 120 V ACinput voltage limits - 3...30 Vvoltage state 0 guaranteed -3...5 Vvoltage state 1 guaranteed 11...30 Vcurrent state 0 guaranteed <= 1.2 mAcurrent state 1 guaranteed >= 2.5 mAinput resistance 4 kOhmdiscrete output current <= 0.15 mA 115 V inductive<= 0.5 mA 115 V resistive<= 1 mA 24 V inductive<= 2 mA 24 V resistive>= 0.005 A 24 Voutput overload protection External by varistor in parallel with each contactoutput short-circuit protection External by varistor in parallel with each contactmechanical durability <= 30000000 cycleselectrical durability <= 100000 cycles inductiveresponse time 2.2 ms from state 0 to state 1 on input3.3 ms from state 1 to state 0 on input10 ms 60 Hz from state 0 to state 1 on output10 ms 60 Hz from state 1 to state 0 on outputisolation between output channels group 1780 V ACisolation between group of I/O channels 1780 V ACisolation between channels and bus 500 V ACpower dissipation 5.5 W<= 8.5 Wprotection type Without protectionassociated fuse rating 4 A fast blow operating voltagemarking CEterminals description PLC n°1 TB(6)IN_DIS#6(10)IN_DIS#10(2)IN_DIS#2(N)PW(8)IN_DIS#8(L1)PW(7)IN_DIS#7(5)IN_DIS#5(4)IN_DIS#4(9)IN_DIS#9(1)IN_DIS#1(3)IN_DIS#3terminals description PLC n°2 (2L1)PW(6)OUT_DIS#6(1)OUT_DIS#1(1L+)PW(7)OUT_DIS#7(5)OUT_DIS#5(2)OUT_DIS#2(3)OUT_DIS#3TB_1(4)OUT_DIS#4(8)OUT_DIS#8current consumption 5 mA 120 V ACdepth 1.87 in (47.5 mm)height 5.57 in (141.5 mm)width 4.92 in (125 mm)product weight 0.57 lb(US) (0.26 kg)Environment product certifications ULCSAFM Class 1 Division 2resistance to electrostatic discharge 4 kV contact IEC 801-28 kV on air IEC 801-2resistance to electromagnetic fields 9.14 V/yd (10 V/m) 80...1000 MHz IEC 801-3ambient air temperature for operation 32...140 °F (0...60 °C)ambient air temperature for storage -40...185 °F (-40...85 °C)relative humidity 95 % without condensationoperating altitude <= 16404.2 ft (5000 m)Offer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- French
- German
User guideSizeAdd to My DocumentsModicon Momentum I/O Base, User Guide (Version 20)Embase d'E/S Modicon Momentum, Guide de l'utilisateur (Version 38)CADSizeAdd to My DocumentsPremium automation platform - Momentum discrete I/O bases (Version 1.0)CertificateSizeAdd to My DocumentsCSA_225844_2591646_MOMENTUM_AUG2017 (Version 1.0)UL E486184 - NRAQ-NRAQ7 (Version 1.0)EAC_RUCFRME83B00168_MOMENTUM_DEC2014 (Version 1.0)Hazloc_cCSAus_225844_70159012_Momentum_feb2018 (Version 1.0)Instruction SheetSizeAdd to My DocumentsMomentum Communication Adapter Ground Screw Installation (Version 08)170ADM39030, 170ADM39031 & 170ARM37030 Momentum I/O Modules – Read Me First (Version 09)Date 14/12/17Size 68.9 KBCatalog PagesSizeAdd to My DocumentsMomentum, entrées-sorties TOR (Version 7.0)Momentum, guide de choix entrées-sorties TOR (Version 6.0)Declaration of conformitySizeAdd to My DocumentsDCC_MOMENTUM_JUL2016 (Version 1.0)ACMA_RCM_MOMENTUM_AUG2013 (Version 1.0)End of Life InformationSizeAdd to My DocumentsModicon Momentum I/O base, Product End-of-Life Instructions (Version 1.0)EU RoHS DeclarationSizeAdd to My DocumentsProduct Environmental ProfileSizeAdd to My DocumentsModicon Momentum I/O base, Product Environmental Profile (Version 1.0)REACh DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Standard Adapter on a Typical BaseDimensions -
Mounting and Clearance
Mounting on a Wall -
Connections and Schema
External Wiring Diagrams3-Wire Sensor with a 2-Wire Actuator4-Wire Sensor with a 3-Wire ActuatorInternal Pin ConnectionsRows 1 through 3 show the internal connections between terminals on the I/O base. Row 4 shows the internal connections on the optional busbar.