    soft starter for asynchronous motor - ATS48 - 156 A - 208..690 V - 37..160 KW

    Show more characteristics >
    Buy online
    No online offers found
    Add to My Favorites Remove from My Favorites

    • Main
      range of product
      Altistart 48
      product or component type
      Soft starter
      product destination
      Asynchronous motors
      product specific application
      Heavy duty industry and pumps
      device short name
      ATS48
      [Us] rated supply voltage
      208...690 V (- 15...10 %)
      motor power kW
      110 kW at 500 V for standard applications
      110 kW at 525 V for standard applications
      110 kW at 660 V for severe applications
      110 kW at 690 V for severe applications
      132 kW at 660 V for standard applications
      160 kW at 690 V for standard applications
      37 kW at 230 V for severe applications
      45 kW at 230 V for standard applications
      75 kW at 400 V for severe applications
      75 kW at 440 V for severe applications
      90 kW at 400 V for standard applications
      90 kW at 440 V for standard applications
      90 kW at 500 V for severe applications
      90 kW at 525 V for severe applications
      motor power hp
      100 hp at 460 V for severe applications
      125 hp at 460 V for standard applications
      125 hp at 575 V for severe applications
      150 hp at 575 V for standard applications
      40 hp at 208 V for severe applications
      50 hp at 208 V for standard applications
      50 hp at 230 V for severe applications
      60 hp at 230 V for standard applications
      power dissipation in W
      For standard applications 391 W
      For standard applications 479 W
      utilisation category
      AC-53A
      type of start
      Start with torque control (current limited to 5 In)
      IcL starter rating
      170 A (connection in the motor supply line) for severe applications
      170 A (connection in the motor supply line) for standard applications
      IP degree of protection
      IP00
      Complementary
      assembly style
      With heat sink
      function available
      External bypass (optional)
      supply voltage limits
      177...759 V
      supply frequency
      50...60 Hz (- 5...5 %)
      network frequency
      47.5...63 Hz
      device connection
      In the motor supply line
      factory setting current
      156 A
      [Uc] control circuit voltage
      110 - 15 % to 230 + 10 %, 50/60 Hz
      control circuit consumption
      30 W
      discrete output number
      2
      discrete output type
      (LO1) logic output 0 V common configurable
      (LO2) logic output 0 V common configurable
      (R1) relay outputs fault relay NO
      (R2) relay outputs end of starting relay NO
      (R3) relay outputs motor powered NO
      output absolute accuracy precision
      +/- 5 %
      minimum switching current
      Relay outputs 10 mA at 6 V DC
      maximum switching current
      Logic output 0.2 A at 30 V DC
      Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms
      Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms
      discrete input number
      5
      discrete input type
      PTC, 750 Ohm at 77 °F (25 °C)
      (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
      discrete input voltage
      24 V (<= 30 V)
      discrete input logic
      Positive logic (Stop, Run, LI3, LI4) state 0 < 5 V and <= 2 mA, state 1 > 11 V and >= 5 mA
      supply inrush current
      Adjustable 0.4...1.3 Icl
      analogue output type
      (AO) current output 0-20 mA or 4-20 mA <= 500 Ohm
      communication port protocol
      Modbus
      connector type
      1 RJ45
      communication data link
      Serial
      physical interface
      RS485 multidrop
      transmission rate
      4800, 9600 or 19200 bps
      installed device
      31
      protection type
      Phase failure (line)
      Thermal protection (motor)
      Thermal protection (starter)
      marking
      CE
      type of cooling
      Forced convection
      operating position
      Vertical +/- 10 degree
      height
      13.39 in (340 mm)
      width
      7.87 in (200 mm)
      depth
      10.43 in (265 mm)
      product weight
      27.34 lb(US) (12.4 kg)
      power range
      30...50 kW at 200...240 V 3 phases
      55...100 kW at 380...440 V 3 phases
      110...220 kW at 480...500 V 3 phases
      motor starter type
      Soft starter
      Environment
      electromagnetic compatibility
      Conducted and radiated emissions conforming to IEC 60947-4-2 level A
      Conducted and radiated emissions conforming to IEC 60947-4-2 level B
      Damped oscillating waves conforming to IEC 61000-4-12 level 3
      Electrostatic discharge conforming to IEC 61000-4-2 level 3
      Immunity to electrical transients conforming to IEC 61000-4-4 level 4
      Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3
      Voltage/current impulse conforming to IEC 61000-4-5 level 3
      standards
      EN/IEC 60947-4-2
      product certifications
      CCC
      CSA
      C-Tick
      DNV
      GOST
      NOM 117
      SEPRO
      TCF
      UL
      vibration resistance
      1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
      1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
      shock resistance
      15 gn 11 ms conforming to EN/IEC 60068-2-27
      noise level
      50 dB
      pollution degree
      Level 3 conforming to IEC 60664-1
      relative humidity
      0...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
      ambient air temperature for operation
      40...60 °C with current derating of 2 % per °C
      14...104 °F (-10...40 °C) without derating
      ambient air temperature for storage
      -13...158 °F (-25...70 °C)
      operating altitude
      <= 3280.84 ft (1000 m) without derating
      > 3280.84...6561.68 ft (> 1000...2000 m) with current derating of 2.2 % per additional 100 m
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      • Spanish
      • French
      Software - Released
      Date
      Size
      Add to My Documents
      SoMove V2.6.5 (FDT Standalone)
      Date 19/06/18
      Size 234.4 MB
      Date 19/06/18
      Size 107.1 KB
      Catalog
      Date
      Size
      Add to My Documents
      Date 02/02/17
      Size 3.6 MB
      Date 02/02/17
      Size 3.8 MB
      User guide
      Date
      Size
      Add to My Documents
      Date 20/02/17
      Size 624.9 KB
      Date 14/06/17
      Size 570.6 KB
      Date 14/12/17
      Size 1.1 MB
      Date 14/02/18
      Size 20.3 MB
      Certificate
      Date
      Size
      Add to My Documents
      Date 19/06/18
      Size 71.4 KB
      Instruction Sheet
      Date
      Size
      Add to My Documents
      Marine certificate
      Date
      Size
      Add to My Documents
      Date 14/07/18
      Size 86.7 KB
      End of life manual
      Date
      Size
      Add to My Documents
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    • Success Stories

      Transtherm Case Study

      Schneider Electric interviewed Transtherm director Tim Bound about our work together. The industry of tomorrow will be different. More volatile markets, new technology capabilities, increased pressure on performance.

      A Tour of Schneider Electric's Modicon M580 ePAC

      Dave Sutton of Schneider Electric gives a guided tour of the features, architecture and benefits of the company's revolutionary ethernet Programmable Automation Controller - ePAC. Learn more on Modicon M580