Canada
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

module XPSAC - Emergency stop - 230 V AC

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSAC
    safety module application
    For emergency stop and switch monitoring
    function of module
    Emergency stop
    Switch monitoring
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SILCL 3 conforming to EN/IEC 62061
    safety reliability data
    DC > 99 % conforming to EN/ISO 13849-1
    MTTFd = 210.4 years conforming to EN/ISO 13849-1
    PFHd = 3.56E-9 1/h conforming to EN/IEC 62061
    type of start
    Unmonitored
    connections - terminals
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1.5 mm² flexible cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² flexible cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² solid cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1 mm² solid cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1.5 mm² flexible cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.25...2 x 1 mm² flexible cable with cable end, with double bezel
    output type
    Relay instantaneous opening 3 NO, volt-free
    number of additional circuits
    1 solid state output
    [Us] rated supply voltage
    230 V AC (- 15...10 %)
    Complementary
    supply frequency
    50/60 Hz
    power consumption in VA
    <= 6 VA AC
    [Uc] control circuit voltage
    230 V
    breaking capacity
    C300: 180 VA, AC-15 (holding) relay output
    C300: 1800 VA, AC-15 (inrush) relay output
    breaking capacity
    1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    6 A per relay relay output
    [Ith] conventional free air thermal current
    10.5 A
    associated fuse rating
    4 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    6 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA relay output
    minimum output voltage
    16 V for relay output
    response time on input open
    <= 100 ms
    [Ui] rated insulation voltage
    300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1
    300 V (degree of pollution: 2) conforming to IEC 60947-5-1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    2 LEDs
    current consumption
    25 mA at 230 V AC (on power supply)
    mounting support
    35 mm symmetrical DIN rail
    product weight
    0.46 lb(US) (0.21 kg)
    Environment
    standards
    EN 60204-1
    EN/ISO 13850
    EN/IEC 60947-5-1
    EN 1088/ISO 14119
    product certifications
    UL
    TÜV
    CSA
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    14...131 °F (-10...55 °C)
    ambient air temperature for storage
    -13...185 °F (-25...85 °C)
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    • German
    • Chinese
    Catalog
    Date
    Size
    Add to My Documents
    Safety modules Preventa XPSAXE, XPSAC For Emergency stop and switch monitoring - Category 0 (Version 2.0)
    Modules de sécurité Preventa XPSAXE, XPSAC Pour surveillance d’Arrêt d’urgence et d’interrupteurs, Catégorie 0 (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD for XPSAC3721P: module XPSAC - Emergency stop - 230 V AC (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.1)
    XPSAC AF AFL AK AR ATE AV Type Examination (Version 2.0)
    Instruction Sheet
    Date
    Size
    Add to My Documents
    XPSAC... Safety module for emergency stop and switch monitoring (Version 00)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Preventa DoC XPSAF XPSAFL XPSAK XPSAR XPSATE XPSAV (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)
    XPS ABV..., XPS AC..., XPS AF..., XPS AX..., XPS BCE..., XPS BF..., XPS DMB..., XPS ECME..., XPS-VC... Safety Modules, Product End-of-Life Instructions (Version 1.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.